Tuesday, January 08, 2008

Not making temperature

As I usually do after any of my modifications, I take the car on a test ride. The bigger the mod the bigger then drive. A friend of mine lives in Lancaster, CA about 50 miles north and slightly east of Burbank. After my last major mod - rerunning the fuel lines - I thought I should take it for a long one.

One important difference is that it is colder there. It's been cool here but colder there.

I headed out around 1pm and it was probably in the 50's where I left. I came home in the evening about 7pm & I would guess it was in low 40's maybe high 30's when I. Now going up the car barely maintained 165º. I generally turn off the electric portion of the oil system when the temp shows around 180, figuring that the system can now maintain itself at a high temperature. And that usually happens, except every so often and it usually happens on the freeway when it's cold, the system will drop temperature. And the turning the electric portion back on doesn't help it just stays where it was

Yesterday was the coldest freeway drive the car has experienced with the conversion. On the way home where it started in the low 40's (again it may have been colder) the car never made it to temperature! It maxed out at 150º and it took it a while to get there. I ended up switch back to diesel and driving home.

Currently I can only think of 2 things that may be the culprit:

1. The electric switch I was using (I replaced it today) was burning up because it was underrated for the amperage draw of the injection line heaters and Vegtherm. This could have led to the Vegtherm & line heaters not receiving the proper about of power to sufficiently heat the oil.*

2. I'm extracting so much coolant heat out of the system that the engine can not produce enough of it. So the oil is actually cooling the coolant with it's thermal requirements. Remember I have the Vormax in the trunk, so by the time the oil returns to the engine it could be cooler than it other wise might be. But then again this must be similar to an in tank heater, which I don't have

I have to post something on the message boards. Any comments?

* Thanks to the boards I realize that I could of / should of used a second relay for the electrical heating part of the system. This would reduce the need to use heavy gauge wire and let me use a lower amperage switch by not passing all the power through the switch and burning it up in the process - live and learn - maybe next time

2007 Journal Archieve


2002 Jetta TDI Sedan

Purchased on ebay w/126k for the conversion

Flipped the switch on June 14th 2006 @ 126,800 miles

www.kungpaojetta.com

December 31th 2007 (135,800)
I guess I should be more specific. My glowplug light is flashing, not "on". This is an indicator of an issue with the brake lights or brake light switch. And guess what, there is a recall on the brakelight switch. I have an appointment scheduled for Friday AM at the dealer. Live & learn



read more



December 30th 2007 (135,800)
I found this glowplug FAQ at TDIclub.com and decided to figure out what is wrong with the glowplugs. As best I can tell they are working. Everything checks so it must be the harness. The harness has previously been replaced because the wires have been cut and taped up. I'm going to add some electrical cleaner and try and find someone with a Vag-Com and clear the codes. Otherwise it will be a new harness.


December 28th 2007 (135,800)
Please see , notes on the 3rd video



November 18th 2007 (135,350)
I've noticed a substantial reduction in the time it takes the oil to get hot once I switch over. This is due I feel to the new Frybrid HE/Filter I recently installed along with the FPHE that was installed earlier.

It's debatable how much of a difference the line heaters make in the initial heating of the oil during and the first part of switch over. They certainly don't hurt.

Remember that I am taking my oil temp reading on the return (looped) line, so I am taking a fairly conservative temperature.

My feeling is that I should install (or again if I was to do it again I would run some) sort of heated fuel line on the journey from the VO tank to the engine bay. Currently there are only portions of the VO line that come in contact with the heated coolant lines. If the lines were heated on the way to the engine bay it would at least act as a preheater to the heaters in the engine bay.

The issue is that the oil currently doesn't spend much time in contact with the heated surfaces. It passes through the heaters but if the fuel lines were heated it would at least preheat the oil before it reaches the heaters in the engine bay there by allowing more heat to be absorbed by the oil on it's journey. I have noticed that the oil will get hotter sooner on surface street driving as opposed to freeway driving. This is because since I am using less oil it stays in contact with the heaters longer before injection

Sept. 29th 2007 (134,439)
Sorry about the lack of updating but I've basically just been driving. I added the Frybrid Heated filter. I had a strange situation where the coolant loop did not heat up after I added the Frybrid filter. After I had some time to think about it (I took the car out for a couple test drives after trying different things - to no avail) and a helpful response to my post on the forum I was able to fix the problem. It was a trapped air pocket. Anyhow the one day project turned into 3 days. I still have to do my final test dives on the veggie part of the system since I was unable to switch over since there was no heated loop.

I also discovered that my injection line heaters weren't coming on. The jumper I made to go from one side to the other is loose and the wire needs to be kept in a particular position for it to work. The Vegtherm is still working so I'm not too worried about it.

I need to run the car for a week or so to make sure nothing is leaking. After that I will insulate the lines and fix the injection line heater. For now I just need to check the line heater once a week or so

Sept 25th 2007 (134,381)
Oil changed, Mobil 1 5-40

August 4th 2007 (133,532)
Just some notes about this overhaul, most of which I have probably mentioned before. The car initially had a stock Plantdrive TDI kit installed . Getting a better understanding of things, or at least my opinions about them led me to change and add some things.

What I don't like:
  • My car has no hose over hose(HOH) or hose in hose(HIH) on the fuel lines. Nor do I have a heated fuel tank. If I were to do it again would added the heated fuel lines. But I am in a realatively mild climate and it was a son of a gun to run those aluminum lines under the car . Most of my oil run under the car is uninsulated aluminum tubing - this I would not do again
  • The Vormax (FPHE) is in the trunk. This to me does not seem like a good idea as there is heat loss on the way up to the engine bay & a section of oil is unheated before the Vegtherm for the initial switchover.
  • The 2 micron Racor filter attached to the back of the Vormax is unheated. Again if I was to do things again I would use something else, perhaps a Frybrid TDI filter or the new Vegmax thast Plandrive sells. I would not go through the hassle of wrapping the Racor. I only did it because I had some leftover tubing around.
It's been about a month now and car is running good. As for the air leak, I found a line with a slit in it near one of the hose clamps.

I have noticed a quick change in temperature when I do the initial switch over but after that the change is not as great as I had hoped. In other word when I switch over the oil will go to 100º rather quickly but after that it take time more time then I would like for it to reach 160º.
I'm thinking that the heater coil around the Racor is more of a passive heater. The quanity of oil it is heating is more then is needed and it can not heat that amount of oil quickly.

To fix this I bought the Frybrid Heated filter. I have yet to receive it but I will replace the racor filter and homemade heater coil with this. My thinking is that the new heater will be using the same amount of heat to heat a smaller quanity of oil because it passes through the heater exchange on it's way to the IP. Imagaine heating a cup of oil vs. heating oil as it passes through a staw. Less oil = more to it

I still have to insulate the lines and do a little replumbing. I will install the Frybrid heater at that time. Perhaps by the end of the month

July 11th 2007 (133,148)
Car has been running fine until today. I had an air leak somewhere in the veggie portion of the system after the intial overhaul. At that time I went back and found one missing hose clamp on a diesel line and double checked all clamps. That seemed to fix it.

The problem that has remerged, is when I am on Veggie and will be making a quick pit stop. I do not purge since the engine is hot and will be off for 15-20 minutes. Depending on how bad the air leak is the car will either start after a couple extra turns or won't start. Right know it starts with an extended starting crank. I think the problem is on the veggie portion as I don't have this issue on the diesel side. I did notice a ton of air in the sight glass while purging and they evetually disappear if a purge while on diesel.

When the car was running fine on veggie before there was no air in the sight glass while purging the one time I looked at itAs amatter of fact I didn't even think it was moving.

The only change in the system since the air leak started again was that I added a hose clamp as a support for the coolant jacket around the 2micron racor, attaching it to a veggie hose to help support the jacket around the racor. The only thing I can think is that perhaps it pulls the veggie hose a certain way introducing air at the nearest connector - stupid perhaps but I don't know what happen

Right now the car drives fine I just have to be aware of leaving it on oil when not running. The easiest fix is to simply switch back to diesel when I turn off the car and switch back to oil when I restart it after these short.

At least that is the plan. Once I get a better idea of what is going on I can better trouble shoot it

July 6th 2007 (133,081)
Major overhaul of the system is complete. Basically the following was done:
  • Replaced the 6 port Pollak with 2 - 3 port Hydraforce valves
  • Moved the 2 micron Racor filter that was in the trunk to the engine compartment and wrapped it in coolant jacket
  • Added a FPHE to the engine compartment, keeping the Vormax in the trunk
  • Added an additional 3 port valve to allow the purged oil to retun to the oil tank during purging, thereby not contaminating the small diesel tank
I'm hoping to get an updated video up and more pictures.



June 1st 2007 (132,831)
Picked up the car yesterday from the local European car mechanic. Evidently the engine cooalnt temp sensor had failed. However according to the mecahnic the on board computer was filled with gibbersih. He asked me if I had hooked up the car to a computer or nythimg, I hadn't. He was wondering about all the "BS" codes the computer was giving him. He did say the sensor had failed some time ago and that it wsn't unusual for the computer to generate gibberish when this sensor fails. He also asked how the car was running because evidentley the ETS regulates the fuel moxture based on the temp is senses.

He said the particular version of the ETS I have was prone to failure and they automatically replace them when they get them in. So he cleared the code and gibbersish and test drove the car. He retested it and another code showed up soemwhere else (I don't remember where it was) but he said because there is so much stuff for them to go through in the menus and such that he caould have mised resetting that one. he drove it again and no problems.

I picked up the car and dove the 3 miles home with no problem. I don't drive this much this time of year so the car will not see much use - or switching over. He did say that if the EML comes on again to bring it in right away so he could check it out.

$175 later, so far so good. . . .I need to recheck the oil level . . ..BTW I never mentioned that the car ran on veggie oil, the only thing asked me about was how long did it take me to do the mod.

May 27th 2007 (132,xxx)
Still waiting to find the time to do the uprades to the VO system. I've been distracted with my other vehicle
and I have a ton of things to do around the house.

The Engine Malfunction Light came on last week. I looked in the owners manual and it mostly relates to emissions. On my old '99 Passat a hose was loose and that caused the EML to come on.

I haven't been driving the car too much and I plan on taking it in next week. I found a European mechanic shop that will charge $75 to hook it up to the VagCom vs the $115 the dealer wants. I have to look in the service manual to get more details but as long as it is not flashing it is OK to drive the car until one can get it to the shop. It takes a minute or 2 for it to come on.

The other thing I'm more concerned about was that I was about a 1/2 quart low on my oil. I checked the oil when the light came on thinking that it was causing the light but it has since sayed on. I need to keep an eye on this

April 6th 2007
(132,371)
Car is running fine. Again not much driving going on here. Just getting ready for the Local Earth Day events. My car and I will be at 2 events - Emerson Elementary's Whole Earth Art Fair on Friday April 20th and Saturday April 21st at the City of Burbank Recycling Center event at the Stough Nature Center.

I've decided to keep the Vormax in the trunk, however I do feel the system needs to be supplemented with additional heat. My solution was to heat the Racor 2 micron filter that is attached to the Vormax bracket with a coolant jacket. I have some extra aluminum tubing from the initial install and I had planned on moving it to the engine compartment and wrapping it with aluminum tubing.

Plantdrive recently introduced VegMax heated 3 micron filter. I think you can also get it with a 5 micron filter. I believe this will eventually replace the Vormax (personally I think you need a variation of both). Rather the me make the coolant jacket I will buy the VegMax.

So the next work on the car will be:
  • Install Vegmax in engine compartment
  • Install return fuel line for oil to returned to veggie tank when purging. This includes an additional switch to be installed in the dash
  • upgrade switch for injection line heaters & Vegtherm to higher capacity - the current one is 30 amps and it gets fairly hot.
The first 2 require a fair amount of plumbing to be done and the last requires the dash to be disassembled again (actually I've done it so many times now I can do that pretty quick) at my pace will require at least 2 days. I should have time to do all this early next month.

In the mean time I have been distracted with my other project


March 12th
(131,874)
I added the injection line heaters this weekend.

The other day, by accident, I started the car on Vegetable oil after parking for 10hrs or so at work. Started fine - I didn't even know it was on Veggie until I went to switch over and it already was running on oil. Unfortunately the Vegtherm didn't get turned on until then. Seems I forgot to purge, turning off the Vegtherm power as opposed to switching back to diesel. I've done this once before but wasn't 100% sure I had done it because the car started right up as if on diesel. Temp was probably in the 50's.

While driving I generally keep an eye on the temp of the oil. Once it hits about 180º I tend to switch off the Vegthem, letting the Vormax do the heating at that point. What I did this time was absentmindedly turn off the Vegtherm and not purge. This just reiterates the drawback of veggie driving - tasks (or in my case, multiple) need to be run. I don't mind doing the procedures as I would think most car nuts wouldn't mind but I can see how a non car person would not want to do this. Some kits will limit the operation to a simple purge process. I keep modifying my setup and this ads to the complications.

Checked the oil level and no drop so hopefully that implies I'm not burning any oil - polymerization. Since I don't drive too much I'm planning on changing oil every 6 months or 4000 miles, this should reduce the chances of polymerization.

Also decided to buy a deep cycle/marine battery to pump the filtered oil. When I bought the Northern Tool 12v fuel pump I thought I would simply use the 12v accessory plug in the trunk. First I had to remove the alligator clips from the pump that are used to power it from battery terminals and replace them with a cigarette power plug. Problem is it draws so much power that it melted the plug I installed.

To make a long story short, I tried it a couple times powering it via the power plug in the trunk and it was a pain - I had to jiggle it to make it work, it would get hot, etc. I also realized that after my last batch of filtered oil that it is best to put the oil in jugs if it is heated and let it settle in case there is any hydrogenated stuff in it so that it would settle out, rather then pumping into the car as I had done before.

I bought the cheapest marine battery Pep Boys had and the least expensive (capacity wise) microprocessor controlled charger I could. The battery was $60 plus $10 core charge & the charger was $50. Total was about $130 w/tax. I've been told this should last about 10 years.
Since I don't have or want to run 11ov out there it is worth it


March 2nd(131,625)
It's cold here again so I'm not switching on my short drives to work. I was hoping that I was over the cold stuff . I did a 25 mile drive in 44-50º weather the other morning and in the 30 minutes I drove it the oil only made it to 150º.

This was primarily all highway driving so I 'm thinking that the Vegtherm can not handle the volume of oil at high rpms and lower temps. Remember the Vormax is in the trunk so it takes a while to heat that quanity of oil in the system and for the Vormax's effect to "kick in". Perhaps a Vegtherm Mega would increase the temperature of the oil more and faster.

I've since discovered that the late model TDI's have a 90 or 120 amp altenator. Mine has a 90 so I think it could handle the vegtherm Mega. However I'm leaning more towards the injection line heaters. The good thing is they heat the oil at the very last entry point to the cylinder head, so there would be very little heat loss and it's past the IP so no heat is lost to it and very little returns to the IP if it is very hot oil . The only thing that bothers me is I don't know how it will be reflected in my temperature readings since most of the oil is burned (I assume) after going through the heaters.


February 22nd(131,425)
I'm still not sure whether the sludge at the bottom of the Vormax is animal fat or hydragenated sludge. When I processed the oil I filled the tank of the car and 4 cubees. I recently gave 2 cubees to a friend and noticed that approx. 20% of one cubee had the creamy stuff on the bottom other had a small amount on the bottom.

The oil was warm/hot when I processed it into the container and car 2 months earlier -I 've only gone thru 1/2 a tank of veggie in 2 months! We then had a fairly severe (by SoCal standards) cold spell where the oil in the Vormax - and I assume the oil in the cubee - settled out (see below). If it is hydragenated stuff at the the bottom it would explain why it didn't settle out during the heating/dewatering process. I may have poured the oil into the prefilter setup and imediately started to heat it for dewatering and filtering. This would have kept it liquid and explain why it settled out at colder tempatures as I have feeling some hydrogenated oils have snuck into my fule system

Initially the stuff in the Vormax looks more granular or pastey then the stuff that was at the bottom of the one cubee. I separated a little sample from the bottom of the final filtering tank and it looks very similar to the settled stuff in the Vormax. I didn't look too much at the stuff in the cubee but it was certainly whiter & whispier then the stuff in the Vormax. I have one more cubee from this batch that I have not looked at to see if there is any creamy stuff on the bottom of it (because it is in the cardboard box it came in).

Perhaps when I change the filter on the Vormax I can scrape the congealed stuff off the bottom of the clear bottom. Until then There's not much to do about. The real test will be to see how the car acts when the veggie gets low in the stock fuel tank - if it clogs it.

I'm getting close to processing another batch and rather then put any in the car imediately I'm going to place it into multiple cubee containers. I think I have about 8 empties available. This way I can let them settle out if there are any problems.

I was hoping to let the tank get low on veggie so I could calculate my MPG but that will have to wait till summer. According to Consumer Reports Veggie has less BTU per gallon than diesel, hence lower MPG.



Winter driving
With my current system and the short drives that I primarily do I have decided not to switch over on the colder days. Since I only drive about 20-25 minutes a day for my commute (8 miles) and it can take 10 minutes or more for the engine to reach operating temp (depending on outside temp) it isn't worth switch to veggie as I would have to purge after a short time. Plus it contaminates the diesel tank with oil with little return.

The bottom line is that perhaps for a month or 2 out of the year I may not drive on Veggie.

January 21st(130,928)
I started a thread about some sediment at the bottom of my Vormax. I'm incline to think it's animal fat. I'm hoping to heat the Lexan bowl in the near future as a test. Hopefully it will dissolve and on a long drive it will get hot enough and reliquify. My concern is what my tank looks like

I also did a quick engine temp test recently because I'm concerned about actual temp of the engine at switch over. It was in the 50's and I took the engine to temp (190º F). I waited an additional minute and the took some temp readings. I'm hoping to post this info soon but in the meantime I feel good about the inital readings being over 200º at the engine head.


Friday, January 04, 2008

C.A.R.B. states and stealerships

As I mentioned previously my glow plug indicator started flashing. Thanks to the helpful info over at TDIclub.com I ended up finding out that the flashing glow plug indicator means something is wrong with your brake lights and/or switch. Why this is the indicator I don't know.

Not realizing that there was a difference between a flashing GP indicator and one that is on all the time, I checked the GP's and they tested good. Somehow in one of my tdiclub.com searches I found out that flashing is related to the brakes and that there was a recall - which I did get a notice for but forgot to deal with it - for the brake switch on my 2002 jetta. I did a quick check of my lights and sure enough they were out except for the center one (thank god).

So I went to my local dealership New Century VW in Glendale CA. When dropping off the car the rep said that the bulbs were most likely burned out because the middle light still worked. Because of the Vormax in the trunk I told them not to replace the right brake light as I didin't want to inccur additional labor charges.

I get a call a few hours later to say they replaced the brake switch and one bulb but the GP indicator is still flashing and that it would be $115 to investigate. I assume that meant hook the car up to a Vag-Com and read the codes. Now I felt pretty sure that the brake switch was the issue based on my research and when I dropped the car off the rep told me they would clear the codes if needed.

When I picked it up, I again asked if they hooked it up to clear the code and he said they did but something else was wrong. At that point I figured I would replace the bulb behind the Vormax and if that didn't fix it I would take to my local euro-car mechanic and have him read the codes for $75 and if they only needed to be cleared I would bill VW for it - there is a reimbursement form with the recall notice.

So I get in the car to leave the dealer an no light. It's working fine. It simply needed to go through a couple cycles to clear the computer. The same thing happen to me when I was checking the GP because I had to disconnect the engine coolant temp sender to engage the GP's and the MIL came on for a few engine cycles then turned it self off

The point here, and it's brought up again and again on the net is that most dealerships don't know much about these TDI's, especially if you live in a CARB state (New York, California, Maine, plus 2 more). You can not buy a new diesel in a CARB state so the dealers don't know the cars . But they are happy to charge me $115 while they try and figure out what they are doing. You need to find a good diesel mechanic in your area or find a dealership experienced with TDI's. Tdiclub.com has a list of recommended diesel mechanics. Stay clear of the dealerships if you can.

Tuesday, January 01, 2008

Notes on 3rd Video

December 28th 2007 (135,800)
Its been cold here (for us anyway - down to the 30's at night) so I haven't been switching over on the short drives to work. I've come to the realization that for the protection of the engine one can not switch over on short trips - especially when it is cold out. I knew this but there is always the instinct to switch over ASAP and be driving for free or helping the enviorment. Perhaps part of my issue is that I have the small diesel tank and I have to be aware of how much of the diesel I use before refilling the small tank so I tend to go to veggie for that reason. But remember I have a trunk!

I found this helpful thread about how to protect your engine on the Biodiesel & SVO Forum

About a week ago the glowplug indicator came on on my TDI. This has made me deal with the 3-port switch placement from the previous modification- that being the installation of the Frybrid HE/filter. The problem is the 3-port switches were mounted to the cowling so I needed to be around whenever anyone service the engine. This hasn't been an issue because the only thing I've done since the switches were moved to the cowling is have an oil changed.

Now that the car needs to go in for service I need to make the system "mechanic friendly" so it's out of the way and provides easy access to the bulk of the engine.

At the same time I decided to do something I have not been looking forward to and that was removing the aluminum lines I had run under the muffler heat shield from the engine bay to the Vormax in the trunk. The problem with this method is that there is no heat exchange between the lines so I'm getting no heat advantage along this run. In this situation cold oil is entering the first heater exchange and as opposed to it being partially heated before the HE and hence getting hotter earlier.

The whole point of these mods is to get the oil as hot as possible when it is first injected into the engine. Although I've seen a significant jump in temps since adding the FPHE it still takes 5-10 minutes for the oil to get to 160 after the switch in this winter weather. This is why I will now generally wait a few more minutes after the water gauge hits 190 to switch over. This extra time hopefully lets the IP get hotter because right now when the water temp reaches 190 the IP is still only warm. This implies to me that the IP is acting like a heatsink and absorbing heat from the heated oil as it passes through it. I can also see the temp raising on the oil near the oil temp sensor the long I wait before switching over - my oil sender is on the looped return line

The only thing left to add is a coolant shut off valve for the hot summer journeys to Las Vegas.

Here is the latest video concerning the above mentioned installation


Friday, December 28, 2007

2006 Journal Archive

2006 Journal Archive


2002 Jetta TDI Sedan

Purchased on ebay w/126k for the conversion


Flipped the switch on June 14th 2006 @ 126,800 miles




December 28th 2006
(130,555)
It's been rather cold here in So Cal - staying in the 50's during the day - so I haven't been switching over as much. With the Vormax in the trunk and the veggie lines lines only partially insulated by HOH, my system is not very robust. It takes longer for the engine to get to temp and since most of my trips are short it isn't worth it as I would shut down shortly after the switch.

I have noticed though with my temp gauge that in this mild winter the car still takes about 10-15 minutes to show the oil at 160º after I switch depending on ambient temp, day/night, etc. With the Vormax in the trunk I know that the VegTherm is doing all the work initially and as the temp gauge indicates it's not enough. I also feel that initially the IP is most likely acting like a heatsink removing heat from the oil as it circulates through it unil it absorb some heat from the block.

A reader emailed me the delima of another Plantdrive owner in So Cal and was wondering why I haven't had any problems. His piston rings are shot and he has had a multitude of problems with his Passat conversion. Again I can only stress that I have only 3000 miles on my conversion, almost exclusively short miles - probably not good for my engine. The reality is I need to use the car & can only do so much to protect it. I also change my oil every 3000 miles since I drive so little. If I were to do it again I would do it differently by building my own more robust system. My car had 126k miles on it and was out of warranty and as the Passat owner said we are fully aware of the consequences of our actions.

I am by no means an expert but early switch over, (see the 11/4/05 entry) as discussed on the forums , will result in "coking" of the pistons rings and other head components. It's very tempting to switch over to soon and enjoy the feeling of driving w/o support from the petrol industry. I for one have been guilty of this. The best way around this is to have an automated system and/or drive a long distance regularly. If you drive alot you'll be more patient about switching over knowing that you have a long drive ahead of you.


November 24th(129,965)
I started to inspect the car this holiday weekend. Since it was several months since the install it was time to go underneath and check the lines and do somemore insulating. I had previously thought I would be supplimenting the system but I don't have the time now nor do I know what to do. I could install and additional FPHE but this may be too much in the summer months. I also thought about a circulating loop as discussed here, as it is more controlable. I figured I would at least add more insulation over the aluminum lines. I'm hoping to update my YouTube video

I'm glad I started the inspection because I found that the Vegtherm was not turning on. After tracking the flow of electricity with a volt meter I found that one of my connections was faulty. I had twisted the wires together and secured it with a electrical cap - the kind that is generally used in home wiring. Somehow the the wire came loose, probably because it wasn't twisted very well.

The last time I checked the Vegtherm was when it was reinstalled on the injectors. I have noticed that the Vegtherm has been inconsistant with it's heating times and the loose wire would explain this. I'll have a better idea now of my heat up times in these cooler winter months

October 14th
I stalled on Veggie

October 7th (129,134)
I moved the Vegtherm back onto the injectors

September 25th
I've decided to put the vegtherm back on top of the injectors - at least I hope to next weekend. With the the temperature gauge I can now monitor the temp and turn off the vegtherm once the oil reaches 160º, as the Vormax seems to be able to maintain the oil's temp in this mild SoCal climate.

One of the reasons I wanted to move it initially off the injectors was because I didn't want the heat from the engine to heat the diesel fuel when the vegtherm was off, as it might transfer some heat from the engine to the vegtherm (this is great when on veggie) . The reality is that with the IP attached to the engine the fuel is getting hot anyway once the engine is at operating temperature. If I feel the return diesel fuel line it is hot from going through the IP.

Another thing I've noticed since switching to the 1/2" tee from the 3/8" for the temp sender is that the gauge takes much longer to register the change in temperature. The gauge may only register 100º but if I feel the hose going to the IP, it feels much hotter. The same for temperature drop when purging.

It is also getting into fall/winter here and getting a little cooler now so any added heat to the system (vegtherm accross injectors) will help. When I first ran the system we were at the start of a record breaking heat wave so I felt I could be getting the oil too hot but now with the temperature gauge as a reference I can turn off the Vegtherm.

Last but not least I decided to order a infrared temperature gauge after talking with a couple of fellow veggie oil users. I bought this one - cheap. The idea being to measure the temperature to compare it to what the gauge in the car says

September 16th
I had a recent air issue in the fuel line. After installing the temp gauge & sender I realized that I shouldn't have use galvanized pipe in the system as this will eventually damage the engine.

Usually I work on the car on weekends when needed. Since I had already installed the temp sender and would simply be swaping the galvanized tee out for another I felt I would be OK doing it midweek. I wanted to remove the galvanized piece ASAP because I didn't now if it was disolving the coating or what. When I did remove it it looked fine. I think this is one of the many things in this conversion that cause problems but over an extended period.

Since I was doing this midweek, I went to Home Depot for the new tee. I had to upsize the tee to 1/2" from 3/8" because I couldn't find a 3/8" black iron tee. No big deal though it's more metal to be heated and I have to upsize the fittings. I remembered from before that they had some brass fittings. I wasn't able to find a 1/2" to 3/8 hose barb but I did find a 1/2" to 3/8" thread adapter. I went ahead and changed out the tee using the new thread adapters in the process.

I took the car out that night and it ran fine. Started fine the next day to go to work. When I left work it started after a beat or so. I went to the auto parts store to get a new switch for the vegtherm - the light on the original switched burned out - strange???.

Got back in the car and it wouldn't start. It sounded like there was no chance it was going to start either. No almost starting, no putter putter, etc. Nothing. I was still on oil because I planned on only being in the store for about 5 minutes. Still being on oil was going to be a problem if I couldn't get it started. I went back in the store to use the restroom & get a razor blade to remove the zipties that were holding on the insulation around the tee(thinking of my options in the process). I came back out and cut the zip ties. I kept trying to start it in 10-15 second s tries as not to overheat the starter. After about 10 minutes of sporatic starting attempts it started. I was just about to give up. I drove the 2 miles to get it home.

When I got home I noticed that the insulation that I removed from the tee was moist - AN AIR LEAK. My mistake was that I didn't put pipe grease on the new brass thread adapter fittings. For some reason I had this crazy idea that brass on brass didn't require pipe dope. Anyhow, I was EXTREMELY relieved to find the cause. Having learned my lesson I simply replaced the tee with a single piece of hose thereby elimenating the extra connections. Car ran fine for the rest of the week.

I ordered the 1/2" NPT to 3/8" barb from Mcmaster.com and installed the new tee this weekend. The car starts and runs fine.

September 3rd
I decided to move the Vegtherm off the injectors, install a temp gauge, and an on/off switch for the Vegtherm. More here.

I also got a wheel alignment and new OEM Michelin tires. The tires on the car a on their way out and bigger then they needed to be. I relaced them with the stock size (195/65HR15 vs 205/60Hr15) and the car feels nimbler, quieter, and easier to turn

August 31st
I think I have figured out the mysterious & rare starting problem . . . low fuel in the diesel tank. Up until this week the car would every once and a while take a few more turns to start then normal. This week the car was having the starting issue all the time when starting cold. It only lasted a few days before I figured it out but I was concerned I would be spending my weekend looking for air leaks.

Previously I had gone 2 weeks without checking the doughnut tank and when I did it had plenty of diesel in it so I assumed that this would be a my mode of operation as I'm still trying to get a grasp of when to check it. After I checked it and discovered it was low I realized that I had driven more on diesel since the last fill up. I made several short errands and even forgot to switch back to veggie on one several mile trip.

So this is good because the doughnut tank does not have a fuel gauge and I drove almost 3 days and didn't run out of gas. I still switched to veggie as I usually do but the car started after a few extra seconds of cranking. Once warm the car would start no problem. The tank still had at least a gallon of diesel in it so i wasn't in danger of running out. This way I get an indication of when I'm running low but can still start the car and get to a station.

Another Plantdrive customer said something to this effect in a conversation I had with him.

July 30th
I've returned to work and started collecting fuel again. Last week I was able to procure about 6 gallons. It's soybean oil and only used once maybe twice. I don't need that much and they don't generate that much. I have a feeling this should work out quite well. The amount will not be the same every week but I hope it will average out to my needs.

I'm currently trying to write the directions for the Plantdrive install. Work & Family keep me busy. I hope to have something in about a month (or 2)


July 18th
Car is starting fine, so I don't know what it is. I'm not really worried about because it isn't the taking 30 seconds to start thing, which indicates an air leak. It also is not consistant and has only happened 3 times so far in a month.

One thing that does concern me is still how much diesel I'm using with this small tank. This car is EPA rated @ 42 city/49 highway. As best I can guess I'm only getting low 30's (VO mileage is equivalent to diesel). Most TDI owners are in the high 30's / low 40's. Granted most of my driving has been city but I thought it would be higher. I'm back to my regualr driving pattern so the constistancy will give me a better idea of the refills needed with diesel

I may have been a little cavalier with the new 4.5 gallon tank thinking that I would get substantially more distance out of it. I did do a few short drives on diesel , never switching over to VO, thinking that it wouldn't be a problem.

July 14th
Again the car is running fine, with one exception on 2 occasions yesterday the car didn't start on the first starter crank. It started within 5 seconds and the engine was warm but not on VO yet. It has only done this once before and I think that was because the dounut tank was low. The only variable is that I changed from the 2 gallon tank to the 4.5 gallon. For various reasons I changed out the fuel p/u tube in the dounut tank. The tube I used was a little short so I had to improvise by adding a piece of rubber fuel line to extend it. The problem is that the tank was full when I did it so I was guessing at it's length. Maybe the tube is kinked (too long). The fact that the problem isn't consistant leads myself & Craig at Plantdrive to believe that it isn't an air leak issue.

Today the car started several time with no problems. The issue is only when on diesel.

I return to work on Monday and that is when the car will see consistant daily use. I only drive about 8 miles each way but it will be consistant. I'm hoping to do about 80% of my drive on VO. Sometimes I will drive further to adifferent location but I'm hoping to figure out how long the dounut tank will last when I go back to my regular routine.

I've reduced the purge to about a minute because I finally realized that the IP (injection pump) circulates oil past the injectors and the injectors only pull what they need from the flow. The excess is returned to the tank (although my system uses a looped return while on VO). So when returning to diesel it only takes about 30 seconds to replace the VO with diesel in the loop. I've been told it takes about another 30seconds (at idle) to burn the oil that is in the injectors. I've been doing this for a couple days now and the car has been starting fine



July 1st
Car is running w/o any problems. Since the last post I took it out to LAX to Palmdale and back to Burbank. Total driving was 180 miles. Car ran perfectly.

It usually takes about 5-7 minutes of driving for the water temp to get to 190ºF. It's been extremely hot here is Southern California so the car is getting to temp quickly. We'll see how it does in the cooler months.

The learning curve is how to make this set up work with short drives, with a 2 gallon diesel tank w/o a guage. Generally speaking I've always tried consolidated my trips to lessen polution. The only way to get the most out of this is not to purge when stopping for short periods. Right now, if on VO, I won't purge if I'm away from the car for no more then 30 minutes. I find that the car holds it heat because as soon as I restart it the water temp returns to 190º. The car has not problems starting on VO.

One problem is that I did not install the forgot-to-purge buzzer. I'm having some problems wiring it correctly but as the name implies it buzzes if you turn off the car and did not purge. My problem is that if I forget to throw the swicth it leaves the vegtherm on and it will drain the battery if left on for an extended period. I've left it on twice so far!

As mentioned above right now it is very hot here so we'll see how things will change as it gets cooler



June 26th

I drove into Hollywwod today while running some errands (about 25 miles roundtrip)to show a friend of mine who helped inspire me to start this project with his talk of the the hydrogen economy a couple years ago.

I flipped the switch after about 6 minutes(190ºF) of driving. When I arrived I didn't purge as I didn't plan on staying long. I DID FORGET TO TURN OF THE VEGTHERM for about 5 minutes. The Vegtherm will drain the battery if left on with the way it is wired. I was supposed to install a buzzer to prevent this but it took so long to install the kit that I just wanted to get my car running. Anyway my buddy was very happy for me and impressed with the car. He peppered me with questions. Over the course of our conversation he called 5 of his neighbors over and I held little info sessions. (If you are thinking about going veggie get ready to be an educator).

As I'm doing this I'm trying to tell people that this is not for everyone. For the people that take the time to listen further I tell them that the system is not great for short commutes becuase you have to wait for the engine to get to temp switch then switch back when your done with the car. I do not have a gas gage on my 2 gallon mini tank so if you run on the diesel alot you drain it very fast. Again I'm learning

I ordered a 3 port valve and some Viton injection return fuel lines from Greaseworks.org to add to my system. The 3 port valve will be added (keeping the Pollak 6 port valve). My Kit has a "Looped" return and there are different camps concerning whether to loop or not. 1 problem with a loop return - IMHO - is that during the purge process the unused oil is sent to the diesel tank and I have a small tank so if purging alot . . . you are contaminating your diesel fuel with every purge. .. .you see how it works.

The 3 port will solve this by letting me have a looped return or a return to tank option. The Viton hose is replace the little fuel line return hoses that connect the injectors. These can degrade with the use of Biodiesl ove a few years.

June 25th


I moved the Racor 2 micron filter slightly today and disconnected a hose in the process, so I took the car out to double check everything when I was done. The TDI has a 12v port in the trunk and I want the option of using that for a 12v pump to get fuel into the tank - the Racor was blocking it. It was in the high 90's today and it took the car about 6 minutes to get to 190ºF. The Vormax was hot to the touch but not up to full heat as it is usually very hot when at operating tempature.


Now the question becomes when to purge. My instincts tell me to purge every time but that doesn't seem practical (I'd have to plan an impulse coffee from 7/11?). My system takes at least a minute to purge and probabley long becasue of where I've placed the Pollak (i'm thinking of moving it). If the engine is at temp I think it is fine to shut down on Veggie for a short period. I have noticed that the engine seems to maintain it's heat for a fairly long period.


June 24th

I've come to conclusion for the way that I will flip the switch, at least for now. I'll wait till the water temp gets to operating tempature - 190ºf/about 5 minutes, maybe throw in a couple minutes more for good luck. Since I live in a mild climate - Southern California - the VeggieTherm is supposed to get the oil to 160º from room tempature (the Voramax will have been working at this point too to heat the oil). Since the oil is at temp (160º before the injection pump) and the engine is at temp it should reduce the chances of polymerization.




My hope is that the oil will not lose much of the tempature as I have placed the Vegtherm on the injectors



June 23rd

Took it out for it's maiden journey, at least any kind of distance. I drove about 60 miles today on SVO up into the Angeles Crest Forest, above Glendale. Curvy and uphill. Every thing worked normally, no problems. I switched after about 10 minutes - 5 minutes for water temp to get to 190F and another 5 minutes added for good measure.


June 22nd
I went out today to run a short errands but did not throw the switch. It was only a couple - 3 miles away so by the time the engine gets hot enough I have to turn it off. This is going to be interesting. Until I install a temp gauge I'm also just guessing, so I'm being a little conservative.

June 21st
Replaced the serpentine tensioner as I damaged it while test driving the Vormax when first installed. The windshield washer pump was loose and got caught in the tensioner and damaged it. Pay Attention! $108 mistake

June 14th
Started the car for the first time on Veggie. Took me 8 days to install. Running on new unused soy oil from Costco

June 6th
Car was given a clean bill of health by TDI mechanic.

June 1. 2006

I'm still tring to work out with the kit manufacturer the appropriate connections. The instructions and kits are written & made in very broad general terms. I've decided after talking with them to run Aluminum under the car. A flare tool was suppose to be delivered today but did not arrive.